PM1401K-3 series of radiation monitors compromises a wide range of all-in-one devices for radiation detection, dose rate and contamination measurements, spectrometry and radionuclide identification.
PM1401K-3P model is the most advanced model in the series suitable for various radiation control tasks including measurement of ambient dose equivalent rate, detection of alpha, beta, gamma and neutron sources, measurement of alpha and beta radiation flux density, acquisition of gamma spectra, identification of radioisotopes, and measurement of food/soil contamination with 137Cs.
(where Ḣ is the measured dose rate value in mSv/h)
± 30 % (45 keV to 15 MeV)
2000 cps per µSv/h (241Am)
5 cps⋅cm2 (thermal neutrons)
(where φ is the measured α-radiation flux density, min-1·cm-2)
(where φ is the measured β-radiation flux density, min-1·cm-2)
1000 scintillation spectra
*when the average dose rate is not more than 0.3 µSv/h; backlight and alarms are activated for not more than 5 minutes per 24 hours
PM1401K-3 series of radiation monitors compromises a wide range of all-in-one devices for radiation detection, dose rate and contamination measurements, spectrometry and radionuclide identification.
PM1401K-3M model is a gamma-only radiation monitor without a neutron detector. The instrument is designed for quick and reliable measurement of gamma dose rate, detection of alpha, beta, and gamma sources, measurement of alpha and beta radiation flux density, acquisition of gamma spectra, identification of radioisotopes, and measurement of food/soil contamination with 137Cs.
(where Ḣ is the measured dose rate value in mSv/h)
± 30 % (45 keV to 15 MeV)
2000 cps per µSv/h (241Am)
(where φ is the measured α-radiation flux density, min-1·cm-2)
(where φ is the measured β-radiation flux density, min-1·cm-2)
1000 scintillation spectra
*when the average dose rate is not more than 0.3 µSv/h; backlight and alarms are activated for not more than 5 minutes per 24 hours
PM1401K-3 series of radiation monitors compromises a wide range of all-in-one devices for radiation detection, dose rate and contamination measurements, spectrometry and radionuclide identification.
PM1401K-3E model is a simplified model without identification and 137Cs activity measurement functions which is designed for fast and accurate detection of alpha, beta, gamma and neutron sources, as well as the measurement of alpha and beta radiation flux density and acquisition of gamma spectra.
± 30 % (45 keV to 15 MeV)
2000 cps per µSv/h (241Am)
5 cps⋅cm2 (thermal neutrons)
1000 scintillation spectra
*when the average dose rate is not more than 0.3 µSv/h; backlight and alarms are activated for not more than 5 minutes per 24 hours