Upgraded PRD PM1703xx-II Series have improved CsI(Tl) detector characteristics and fully comply with ANSI N42.32-2016.
The extended measurement range is enabled by the installed new CsI(Tl) detector with a semiconductor photomultiplier (SiPM).
* Instruments of PM1703xx-II Series were successfully tested in ORNL.
PM1703GNA-II is a gamma-neutron PRD, which has such competitive features as high sensitivity, compact size, user-friendly interface, low-energy operation, waterproof and shockproof case.
The instrument can be used in both indoor and outdoor environments for detection and localization of gamma and neutron radiation sources and measurement of dose equivalent rate (DER).
DER measurement mode | 0.06 – 1.33 MeV |
Search mode | 0.033 – 3.0 MeV |
Neutron | thermal to 14.0 MeV |
Operation Principle
As well as previous well-known modifications of PRD PM1703 Series, PM1703GNA-II continuously monitors the environment for radiation, measures personal Dose Equivalent Rate (DER) of gamma raiation and alerts the user with visual, audio and/or vibrating alarm if a radiation source is detected. The readings of the instrument are displayed in counts per second for both neutron and gamma detectors and the search algorithm based on background calibration is used. The Instrument has “Mode 0…9” , which is designed to display the current level of gamma radiation background in the form of digits from 0 to 9. Instrument is equipped with 6LiF/ZnS-screen based neutron detector, which complies with ANSI N42.32-2016 requirements.
All operations history is stored in the instrument non-volatile memory (up to 2000 data points), protecting the data even when the battery is removed. The stored data can also be transferred to the PC via USB interface. Storing data format is designed to meet ANSI N42.42.
Supress NORM algorithm
This algorithm allows excluding alarm signal when the natural gamma background value increases and Naturally Occurring Radioactive Materials (NORM) are detected. If NORM are detected - green indication light is given. In the case the other radionuclides types (IND, NUC, MED) are detected, red indication light and sound alarm are activate
Modifications
- PM1703GNA-II - (basic model) is designed to detect, search, and localize gamma and neutron radioactive sources by their external gamma and neutron radiation, as well as to measure personal Dose Equivalent Rate (DER) of gamma radiation;
- PM1703GNA–II BT - additionally to the functions of the basic model, is equipped with Bluetooth radio channel that enables the function of smartphones communication;
- M1703GNA–II MBT – differs from the basic model by extended range of DER measurement, availability of personal Dose Equivalent (DE) measurement and Bluetooth.
Options
- PM1703GNA-II can be equipped with holster that provides additional protection in various weather conditions. It can be also fixed on the waist belt using belt loop.
- PM1703GNA-II can be equipped with telescopic extension pole for operating in remote and hard-to-reach areas.
Detector
|
Csl(TI) SiPM; 6LiF/ZnS | ||||||
Dose equivalent rate (DER) measurement range
|
0.1 µSv/h – 300 µSv/h (10 µrem/h – 30 mrem/h) | ||||||
DER measurement accuracy
|
± 30% | ||||||
Energy range
|
|
||||||
Alarm Type
|
light, audible and vibration | ||||||
Ingress protection
|
IP65 | ||||||
Memory
|
no less 2000 data points | ||||||
Power supply
|
one AA size alkaline or rechargeable battery 2000 mAh (recommended) | ||||||
Battery Lifetime
|
up to 800 h | ||||||
Weight
|
240 g. | ||||||
Operating temperature
|
-40 to+50°C (-40°F to +122°F) | ||||||
Atmospheric pressure
|
84 to 106,7 kPa | ||||||
Dimensions
|
87x72x32 mm (3.43 x 2.81 x 1.25 in.) | ||||||
Humidity
|
up to 98% at +35°C (95°F) | ||||||
Mean service lifetime
|
no less than 8 years | ||||||
Data exchange
|
USB | ||||||
Response time
|
0.25 s | ||||||
Sensitivity, neutron radiation
|
|