The compact instrument with integrated functions of simultaneous monitoring of both radiological and chemical environment.
Features:
The Combined Gamma Radiation and Chemical Agent Detector PM2012M consist of two independent modules:
Gamma-radiation detector module
Registration of the gamma radiation is carried out on the basis of Geiger-Muller counter, enabling continuous monitoring of the ambient dose equivalent rate and dose equivalent of gamma radiation and alarming when the preset threshold levels are exceeded.
Toxic chemical vapors detection module
Detection of the presence of toxic vapors in the air is carried out with the help of ionization chamber, equipped with beta-radiation source 63Ni , The analyzed air is pumped trough the chamber for simultaneous independent detection of organophosphorous compounds and arsenic-containing substances takes place.
For indication of toxic substances steams detection two analogue scales are used: Yellow for indication of organophosphorous compounds detection and red for indication of arsenic-containing substances detetction.
The number of the illuminated segments (from the bottom) indicated level of steams of toxic substances concentration as the ratio of the current value to the threshold value in %:
- one segment – from 75 to 99;
- two segments – from 100 to 124;
- three segments – from 125 and more.
The instrument is equipped with high contrast OLED indicator for clear reading even under direct sunlight.
The forma factor of PM2012M instrument, its metallic shock and water-resistant case allow for using the instrument personnel in severe weather and operating conditions. The instrument is easy-to-use and requires minimal training.
| PM2012M | |
|---|---|
| Detectors | |
Gamma-radiation detector | Geiger-Muller counter |
Chemical warfare agent | Ion Mobility Spectrometry (IMS) |
| Dose rate measuring range | 1 µSv/h - 10 Sv/h |
| Dose rate accuracy (H - dose rate, µSv/h) | ± (15 + 20/H) % |
| Dose measurement range | 1 µSv - 10 Sv |
| Dose accuracy | ± 15 % |
| Dose rate threshold range | 0.01 up to 999 mSv/h |
| Gamma radiation energy range | 0.06 – 3.0 MeV |
| Energy response relative to 0.662 MeV (Cs-137) | ± 30 % |
| Detection time of exceed threshold concentration (at normal climatic conditions: temperature +20° C ±5°C, atmospheric pressure 101.3 (+5.4; -17.3) kPa, relative humidity 60 (+20; -30) %) | |
threshold for organophosphorous compounds detection 5*10-5mg/l, no more than | 10 s |
threshold for arsenic-containing compounds detection 5*10-4mg/l, no more than | ![]() |
threshold for arsenic-containing compounds detection 3*10-4mg/l, no more than | 15 s |
| Detection time of step increase or decrease of gamma-radiation dose equivalent rate from 10 to 100 mSv/h, no more than | 10 s |
| Power supply | one D type galvanic battery |
| Batteries lifetime, not less than | 150 h |
| Operating conditions | |
temperature range | -10 to +60°C (-14 to +140 °F) |
relative humidity | up to 98% at 35°C (95°F) |
pressure | from 84 to 106.7 kPa |
| Case protection (non-operating condition) | IP41 |
| Weight, not more than | 770 g |
| Dimensions | 66 x 47 x 195 mm |